The study of pulse transformer is one of the key problems of pulsed power conditioning system.The technical requirement and the construction parameters of the pulse transformer are presented.Test results of the transformer are also given.The inductance of the primary coil is 3.6μH,and the coupling efficiency is 0.77.When input voltage is 60kV,output voltage can be 500kV.%在脉冲功率调制系统研究中,其核心技术之一是脉冲变压器的研制。本文描述了脉冲变压器的技术要求和结构参数设计,并给出了实验测试结果:变压器的初级电感为3.6μH,耦合系数为0.77。当初级输入电压为60kV时,次级输出电压可达到500kV。